Avanos Grup
ÜrünlerGeniş Ürün Yelpazesi ile Medikal Ürün Tedariki

Interbody Fusion Cage Mesh

Interbody Fusion Cage Mesh
Designed by BONE Medical Co., Ltd. and being used for total knee arthroplasty.Teklif Al
Ürün Açıklaması

Cemented total knee arthroplasty (TKA) implant. Including 4 components: KF1B00 Femoral Component, KI1B45 Tibial Insert, KT1B01 Tibial Tray and KP1B45 Patella Component.

Indication: Severely pain or immobility caused by osteoarthritis, traumatic arthritis or rheumatoid arthritis.

The BONE01 Total Knee Replacement Implant can reduce pain and increase the mobility of patient by replacing damaged knee joint articulation in patients and reestablish the function and alignment of knee

Material: KF1B00 Femoral Component, Co-Cr-Mo Alloy

KI1B45 Tibial Insert, UHMWPE

KT1B01 Tibial Tray, Co-Cr-Mo Alloy

KP1B45 Patella Component, UHMWPE

Component.Spec.:

KF1B00 Femoral Condyle, 0.5,1, 2, 3, 4, 5, 6, each contains left and right, 14 specifications in total.

KI1B45 Tibial Insert, 0, 1, 2, 3, 4, 5, each size contains height 9/11/13/15, 24 specifications in total.

KT1B01 Tibial Tray, 0, 1, 2, 3, 4, 5, 6 specifications in total.

KP1B45 Patella Component, 00, 0, 1, 2, 3, 5 specifications in total.

Features & Benefits

image001

Ø Classic design examined by long period of clinical trails.

Ø High interchangeability, a single insert size can work with 3 femoral sizes, vice versa.

Ø Highly polished articular surfaces, decrease wear rate.

Ø Intercondylar box stabilized design, simple but reliable.

Ø Anatomical patello-femoral trochlear groove design.

Ø 7°patello-femoral trochlear groove, closely match normal anatomy

Ø Implanted using BONE 01 Total Knee Replacement Implant Surgical Instrument, this combination has been examined by clinical applications.

Notes in surgery:

Ø Fully evaluate condition of patient knee with X-ray examination before surgery.

Ø Choose correct implant specification during surgery.

Ø Use BONE 01 Total Knee Replacement Implant Surgical Instrument to evaluate and balance flexion-extension clearance before implant components.

Ø The alignment and the balance of soft tissue should be carefully finished during surgery.

Ø Reuse of implant is strictly prohibited.

Ø When implant prosthesis, do not scratch articulation surfaces.

Packaging & Delivery

Packaging

Inner: Two layers of sterile package, both are Tyvek + PETG heat-sealing package, covered by carton and heat shrinkable films

External: Standard carton

Lead Time

7-21 days

Delivery

≤30kg, Door to door (DHL/TNT/UPS/FEDEX/EMS, etc.)

>30 kg, Airport to Airport

By air or by sea

header-image
Avanos Group, which is the address of quality in healthcare, continues to provide the best service to its customers with its experience in the sector for many years.
Avanos GrupAvanos GrupAvanos GrupAvanos Grup
Copyright © 2025 Fovimarlo Agency / All Rights Reserved | Terms and Conditions | Privacy Policy