Avanos Grup
ÜrünlerGeniş Ürün Yelpazesi ile Medikal Ürün Tedariki

Lhotse Cementless Hip Replacement Implant

Lhotse Cementless Hip Replacement Implant
Patented design of BONE medical device Biomaterial Co., Ltd. and being used for hip arthroplasty.Teklif Al
Ürün Açıklaması

Cementless implant, can be used in both total and partial hip arthroplasty. Consists of 5 components: S5A17 Femoral Stem, H1C00 Changeable Femoral Head, L5A45 Polyethylene Liner, M5A17total hip metal cup A5A10 Acetabular Cup Screw and D1C50 Bipolar Femoral Head for partial hip arthroplasty.

Indication:

Material: S5A17 Femoral Stem, Titanium Alloy with Titanium coating

H5C00 Changeable Femoral Head, Co-Cr-Mo Alloy

L5A45 Polyethylene Liner, UHMWPE

M5A17total hip metal cup, Titanium Alloy with Titanium coating

A5A10 Acetabular Cup Screw, Titanium Alloy

D1C50 Bipolar Femoral Head Co-Cr-Mo Alloy+ UHMWPE

Component Spec.:

S5A17 Femoral Stem, 1,2,3,4,5,6,7,7.5,8,8.5;

H5C00 Changeable Femoral Head, 22/M, 22/L, 28/S, 28/M, 28/L, 28/XL

L5A45 Polyethylene Liner, 38/22,40/22,42/28, 44/28, 46/28, 48/28, 50/28, 52/28, 54/28

M5A17total hip metal cup, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 60

A5A10 Acetabular Cup Screw, Φ6.5×15, Φ6.5×20,Φ6.5×25,Φ6.5×30,Φ6.5×35,Φ6.5×40

D1C50 Bipolar Femoral Head,Φ38/22,Φ40/22,Φ42/22,Φ44/22,Φ46/28, Φ48/28, Φ50/28, Φ52/28, Φ54/28

Features & Benefits

Ø Classic design examined by long period of clinical trials.

Ø Stem and cup made by wrought titanium alloy, with excellent modular of elastic, high strength, and good biocompatibility.

Ø Plasma sprayed titanium coating with porous structure on the surface of stem and cup, facilitates in-growth of bone

Ø Recommended head/neck ratio design, which enables better ROM (range of motion).

Ø Anti-rotation scallops for cup and polyethylene liners provide rotational stability

Ø Optimized design, implant sizes match anatomical data.

Notes in surgery:

Ø Cement-less Hip suitable for young-aged patient whose bone has good quality

Ø Resistance and chatter from cortical engagement may be used as a signal to cease taper reaming;

Ø Ensure sequential reaming is completed before broaching. If the broach size is countersunk more than 4mm below the neck resection, re-evaluate the resection level. If the neck resection level is determined to be correct ream up and use the next size broach.

header-image
Avanos Group, which is the address of quality in healthcare, continues to provide the best service to its customers with its experience in the sector for many years.
Avanos GrupAvanos GrupAvanos GrupAvanos Grup
Copyright © 2025 Fovimarlo Agency / All Rights Reserved | Terms and Conditions | Privacy Policy